Homepage
|
Profile
|
Product
|
Project
|
Video
|
News
|
Leave message
|
Contact us
Homepage
>
Product
Product
Vacuum Emulsifying Mixer Series
Liquid Mixer series
Perfume Series
Filling & Packing Series
Water Treatment Series
Sanitary Storage Tank Series
Lab Equipment Series
Special Mixer Series
Perfume refrigerator
hot:2144
Application
This unit can be used in the production of perfume, lotion, body lotion, cream, toilet water and other products.
Function
mix、cool、filter
Feature
1 diaphragm pump can be equipped with self suction feeding, without the need for manual feeding.
2 the two-stage filter fineness of up to 0.2 m, can filter out impurities.
3 the lowest refrigeration temperature of -5 DEG C, the temperature control is simple and easy to operate.
4 circulation system, products can be recycled and filtering.
5 wheel design, convenient to move.
6. The connection part of the clamp design, easy assembly and disassembly, convenient cleaning, maintenance.
Technical Parameter
Cooling HP
3P
Tank capacity
200L
Power supply
220V or 380V; 50Hz or 60Hz
Power
2.2KW
Max Freeze temp
-5℃
Cooling media
R22
Pressure
0.5-0.6Mpa
One stage filter finess
1.0µm
Two stage filter finess
0.2µm
Notice
1, the new machine before use, this machine has grounded three-phase 30A four core socket is reliable, and the frame ground;
2, the new machine before use, the device is connected.
3, water booster pump for the diaphragm pump, air source to drive it to run, for the single;
4, in the freezer before the operation, check the chiller is high or low pressure protection device is adjusted to the appropriate parameters, pressure alarm is adjusted to 2.0MPA, low voltage alarm set to 0.7MPA. (a process completed by supplier)
5, in the freezer before the operation, check the "air-cooled" the direction of the fan, the check procedure: first start the panel "refrigeration switch" button, immediately stop "refrigeration switch" button, the running direction is the same visual equipment signs in the same direction, if not can not start the refrigeration unit, otherwise damage to the refrigeration unit, can be exchanged through the power line into the line direction.
6.Before starting, cooling tank with sufficient material, otherwise the cooling coil in the absence of material contact condition, will cause the refrigeration unit load increased to generate fault.
×
QME-500L Vacuum Emulsifying Mixer
QME-1000L Vacuum Emulsifying Mixer
QME-400L Vacuum Emulsifying mixer
QME-800L Vacuum Emulsifying mixer
QME-500L Washing mix
QME-50L Vacuum Emulsifying Mixer
QME-150L Vacuum Emulsifying Mixer Serise
QMDJ-200L Cold water machine
1000L Liquid mixer
2000L Vacuum Emulsifying Mixer
Vertical mobile filling machine
Vacuum system
Rotor pump
QMGJ-1000L Vacuum Emulsifying
5 t vacuum emulsifying machine
Liquid filling machine
Lipstick equipment
Decentralized mixer
QMRJ-1 vacuum emulsifying mixer
QMGJ-1 vacuum emulsifying mixer
×